Universal CLP-100NI-NPRT Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Drukuj i skanuj Universal CLP-100NI-NPRT. Universal CLP-100NI-NPRT User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 87
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Computer-Based
Instruments
NI 5102 User Manual
High-Speed Digitizer
NI 5102 User Manual
June 2001 Edition
Part Number 321390D-01
Przeglądanie stron 0
1 2 3 4 5 6 ... 86 87

Podsumowanie treści

Strona 1 - Instruments

Computer-BasedInstrumentsNI 5102 User ManualHigh-Speed DigitizerNI 5102 User ManualJune 2001 EditionPart Number 321390D-01

Strona 2

© National Instruments Corporation 1-1 NI 5102 User Manual1IntroductionThis chapter describes the National Instruments (NI) 5102 and listsadditional e

Strona 3 - Important Information

Chapter 1 IntroductionNI 5102 User Manual 1-2 ni.comTo improve timing resolution for repetitive signals, you can use randominterleaved sampling (RIS)

Strona 4 - Compliance

Chapter 1 Introduction© National Instruments Corporation 1-3 NI 5102 User ManualFigure 1-1. The Relationship Between the Programming Environment,NI-DA

Strona 5 - Compliance to EU Directives

Chapter 1 IntroductionNI 5102 User Manual 1-4 ni.comNI-SCOPE DriverThe NI-SCOPE driver is the preferred choice to program your NI 5102.It provides fle

Strona 6 - Contents

Chapter 1 Introduction© National Instruments Corporation 1-5 NI 5102 User ManualNoteNI 5102 digitizers use only the easy I/O interface under data acqu

Strona 7

Chapter 1 IntroductionNI 5102 User Manual 1-6 ni.comPXI-specific features, RTSI bus trigger, RTSI Clock, and SerialCommunication are implemented on th

Strona 8 - About This Manual

© National Instruments Corporation 2-1 NI 5102 User Manual2Installation and ConfigurationThis chapter describes how to unpack, install, and configure

Strona 9 - Related Documentation

Chapter 2 Installation and ConfigurationNI 5102 User Manual 2-2 ni.com– NI 5102 (USB)NI 5102 (USB) power supply❑Vinyl pouch for storing cables and acc

Strona 10 - Introduction

Chapter 2 Installation and Configuration© National Instruments Corporation 2-3 NI 5102 User ManualInstalling the NI 5102There are two main steps invol

Strona 11 - Chapter 1 Introduction

Chapter 2 Installation and ConfigurationNI 5102 User Manual 2-4 ni.comHardware ConfigurationThe NI 5102 is a fully software-configurable, Plug and Pla

Strona 12 - NI-DAQ, and Your Hardware

SupportWorldwide Technical Support and Product Informationni.comNational Instruments Corporate Headquarters11500 North Mopac Expressway Austin, Texas

Strona 13 - NI Application Software

© National Instruments Corporation 3-1 NI 5102 User Manual3Digitizer BasicsThis chapter explains basic information about using digitizers, includingim

Strona 14 - Using PXI with CompactPCI

Chapter 3 Digitizer BasicsNI 5102 User Manual 3-2 ni.comAnalog BandwidthAnalog bandwidth describes the frequency range (in hertz) in which asignal can

Strona 15 - Optional Equipment

Chapter 3 Digitizer Basics© National Instruments Corporation 3-3 NI 5102 User ManualSample RateSample rate is the rate at which a signal is sampled an

Strona 16 - What You Need to Get Started

Chapter 3 Digitizer BasicsNI 5102 User Manual 3-4 ni.comVertical SensitivityVertical sensitivity describes the smallest input voltage change the digit

Strona 17 - Unpacking

Chapter 3 Digitizer Basics© National Instruments Corporation 3-5 NI 5102 User Manualrate of 20 MHz, the duration of acquisition is 5 ms (100,000 × 50

Strona 18 - Installing the NI 5102

Chapter 3 Digitizer BasicsNI 5102 User Manual 3-6 ni.comFigure 3-5. Dynamic Range of an 8-Bit ADC with Three Different Gain Settings• Source impedance

Strona 19 - Hardware Configuration

Chapter 3 Digitizer Basics© National Instruments Corporation 3-7 NI 5102 User Manualbuffering. See the Understanding the Probe and Its Effectson Your

Strona 20 - Digitizer Basics

Chapter 3 Digitizer BasicsNI 5102 User Manual 3-8 ni.comUnderstanding the Probe and Its Effectson Your WaveformSignals travel from the tip of the prob

Strona 21 - Analog Bandwidth

Chapter 3 Digitizer Basics© National Instruments Corporation 3-9 NI 5102 User ManualAnalytically, obtaining a flat frequency response means:Rin/(Rin+R

Strona 22 - Sample Rate

Chapter 3 Digitizer BasicsNI 5102 User Manual 3-10 ni.comFigure 3-7. Connecting the Probe Compensation CablingAs shown in Figure 3-8, an undercompensa

Strona 23 - Record Length

Important InformationWarrantyThe NI 5102 is warranted against defects in materials and workmanship for a period of one year from the date of shipment,

Strona 24 - Making Accurate Measurements

Chapter 3 Digitizer Basics© National Instruments Corporation 3-11 NI 5102 User ManualFigure 3-8. Probe Compensation ComparisonActive and Current Probe

Strona 25 - Chapter 3 Digitizer Basics

© National Instruments Corporation 4-1 NI 5102 User Manual4Hardware OverviewThis chapter includes an overview of the NI 5102, explains the operation o

Strona 26

Chapter 4 Hardware OverviewNI 5102 User Manual 4-2 ni.comFigure 4-2 shows a block diagram of the NI 5102 (PCMCIA, USB).Figure 4-2. NI 5102 (PCMCIA, US

Strona 27 - Passive Probe

Chapter 4 Hardware Overview© National Instruments Corporation 4-3 NI 5102 User ManualThe NI 5102 (PCI, ISA) gives you direct BNC connectivity on the b

Strona 28 - How to Compensate Your Probe

Chapter 4 Hardware OverviewNI 5102 User Manual 4-4 ni.comThe NI 5102 (USB) gives you direct BNC connectivity, as shown inFigure 4-5.Figure 4-5. NI 510

Strona 29 - I/O Connectors

Chapter 4 Hardware Overview© National Instruments Corporation 4-5 NI 5102 User ManualFigure 4-6.NI 5102 (PXI) I/O ConnectorsSignal ConnectionsYou can

Strona 30 - Active and Current Probes

Chapter 4 Hardware OverviewNI 5102 User Manual 4-6 ni.comSerial Communications Port (AUX)♦ NI 5102 (PXI)The serial communication port, AUX, provides +

Strona 31

Chapter 4 Hardware Overview© National Instruments Corporation 4-7 NI 5102 User ManualThe CH0, CH1, and TRIG channels have a software-programmablecoupl

Strona 32 - I/O Connector

Chapter 4 Hardware OverviewNI 5102 User Manual 4-8 ni.comADC Pipeline DelayThe ADC on the NI 5102 is a pipelined flash converter with a maximumconvers

Strona 33 - Figure 4-3

Chapter 4 Hardware Overview© National Instruments Corporation 4-9 NI 5102 User ManualNoteIf Scan Clock is externally supplied, you must supply a free-

Strona 34 - Chapter 4 Hardware Overview

ComplianceFCC/Canada Radio Frequency Interference Compliance*Determining FCC ClassThe Federal Communications Commission (FCC) has rules to protect wir

Strona 35 - Signal Connections

Chapter 4 Hardware OverviewNI 5102 User Manual 4-10 ni.comTable 4-5 describes the posttrigger acquisition signals.Table 4-5. Posttrigger Acquisition S

Strona 36 - Analog Input

Chapter 4 Hardware Overview© National Instruments Corporation 4-11 NI 5102 User ManualPretrigger AcquisitionIn pretrigger acquisition mode, the device

Strona 37 - Table 4-3

Chapter 4 Hardware OverviewNI 5102 User Manual 4-12 ni.comFigure 4-9 shows the relevant timing signals for a typical pretriggeredacquisition. The illu

Strona 38 - Posttrigger Acquisition

Chapter 4 Hardware Overview© National Instruments Corporation 4-13 NI 5102 User ManualTable 4-7 describes the pretrigger acquisition signals.Table 4-7

Strona 39 - Table 4-4

Chapter 4 Hardware OverviewNI 5102 User Manual 4-14 ni.comTrigger SourcesThe Scan Clock, Start Trigger, and Stop Trigger signals can be generatedthrou

Strona 40

Chapter 4 Hardware Overview© National Instruments Corporation 4-15 NI 5102 User ManualAnalog Trigger CircuitThe NI 5102 contains a sophisticated analo

Strona 41 - Pretrigger Acquisition

Chapter 4 Hardware OverviewNI 5102 User Manual 4-16 ni.comFigure 4-11. Pretrigger and Posttrigger Acquisitions with Hold-offNoteWhen you use trigger h

Strona 42

Chapter 4 Hardware Overview© National Instruments Corporation 4-17 NI 5102 User ManualRandom Interleaved SamplingThe NI 5102 supports Random Interleav

Strona 43

Chapter 4 Hardware OverviewNI 5102 User Manual 4-18 ni.comyour NI 5102 and afterwards whenever operating environment conditionschange.Externally recal

Strona 44 - Trigger Sources

Chapter 4 Hardware Overview© National Instruments Corporation 4-19 NI 5102 User ManualFigure 4-12.RTSI Bus Trigger LinesThe RTSI bus clock line is a s

Strona 45 - Trigger Hold-off

Canadian Department of CommunicationsThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Strona 46

Chapter 4 Hardware OverviewNI 5102 User Manual 4-20 ni.comPFI LinesAll NI 5102 digitizers have two multipurpose programmable functiondigital input/out

Strona 47 - Calibration

Chapter 4 Hardware Overview© National Instruments Corporation 4-21 NI 5102 User Manual• Analog Trigger Circuit Output—This signal is the digital outpu

Strona 48

Chapter 4 Hardware OverviewNI 5102 User Manual 4-22 ni.comMaster/Slave OperationYou can use two or more NI 5102 digitizers in one system to increase t

Strona 49 - RTSI Bus Trigger Lines

Chapter 4 Hardware Overview© National Instruments Corporation 4-23 NI 5102 User Manual3. Program the master device to output its internal timebase on

Strona 50 - PFI Lines

© National Instruments Corporation A-1 NI 5102 User ManualASpecificationsThis appendix lists the specifications of the NI 5102. These specificationsar

Strona 51

Appendix A SpecificationsNI 5102 User Manual A-2 ni.comInput signal ranges (CH0, CH1)(without probe attenuation) ...±5 V at gain of 1

Strona 52 - Master/Slave Operation

Appendix A Specifications© National Instruments Corporation A-3 NI 5102 User ManualTransfer CharacteristicsRelative accuracy ...

Strona 53

Appendix A SpecificationsNI 5102 User Manual A-4 ni.comTriggersAnalogSource ...CH0, CH1, TRIGLevel .

Strona 54 - Specifications

Appendix A Specifications© National Instruments Corporation A-5 NI 5102 User ManualRTSI (NI 5102 for PCI, PXI, ISA Only)Trigger lines ...

Strona 55 - Timebase System

Appendix A SpecificationsNI 5102 User Manual A-6 ni.comMaximum Working Voltage(Signal voltage plus common-mode voltage)Channel to earth...

Strona 56 - Stability

© National Instruments Corporation vii NI 5102 User ManualContentsAbout This ManualConventions Used in This Manual...

Strona 57 - Digital (PFI1 and PFI2)

Appendix A Specifications© National Instruments Corporation A-7 NI 5102 User Manualby your product, and a link to the DoC (in Adobe Acrobat format) ap

Strona 58 - Physical

© National Instruments Corporation B-1 NI 5102 User ManualBTechnical Support ResourcesWeb SupportNI Web support is your first stop for help in solving

Strona 59 - Electromagnetic Compatibility

Appendix B Technical Support ResourcesNI 5102 User Manual B-2 ni.comWorldwide SupportNI has offices located around the world to help address your supp

Strona 60

© National Instruments Corporation G-1 NI 5102 User ManualGlossaryPrefix Meaning Valuep- pico- 10–12n- nano- 10–9µ- micro- 10–6m- milli- 10–3k- kilo-

Strona 61 - Technical Support Resources

GlossaryNI 5102 User Manual G-2 ni.comAC coupled allowing the transmission of AC signals while blocking DC signalsADC analog-to-digital converter—an e

Strona 62 - Worldwide Support

Glossary© National Instruments Corporation G-3 NI 5102 User Manualbandwidth the range of frequencies present in a signal, or the range of frequencies

Strona 63 - Glossary

GlossaryNI 5102 User Manual G-4 ni.comchannel pin or wire lead to which you apply or from which you read the analog ordigital signal. Analog signals c

Strona 64

Glossary© National Instruments Corporation G-5 NI 5102 User Manualcounter/timer a circuit that counts external pulses or clock pulses (timing)coupling

Strona 65

GlossaryNI 5102 User Manual G-6 ni.comDC coupled allowing the transmission of both AC and DC signalsdefault setting a default parameter value recorded

Strona 66

Glossary© National Instruments Corporation G-7 NI 5102 User ManualDOS disk operating systemdown counter performing frequency division on an internal s

Strona 67

ContentsNI 5102 User Manual viii ni.comChapter 4Hardware OverviewI/O Connector ...

Strona 68

GlossaryNI 5102 User Manual G-8 ni.comexpansion ROM an onboard EEPROM that may contain device-specific initialization andsystem boot functionalityexte

Strona 69

Glossary© National Instruments Corporation G-9 NI 5102 User ManualGgain the factor by which a signal is amplified, sometimes expressed in decibelsgain

Strona 70

GlossaryNI 5102 User Manual G-10 ni.cominput bias current the current that flows into the inputs of a circuitinput impedance the measured resistance a

Strona 71

Glossary© National Instruments Corporation G-11 NI 5102 User ManualKkkilo—the standard metric prefix for 1,000, or 103, used with units ofmeasure such

Strona 72

GlossaryNI 5102 User Manual G-12 ni.comMFLOPS million floating-point operations per second—the unit for expressing thecomputational power of a process

Strona 73

Glossary© National Instruments Corporation G-13 NI 5102 User ManualNRSE nonreferenced single-ended mode—all measurements are made withrespect to a com

Strona 74

GlossaryNI 5102 User Manual G-14 ni.comPGIA programmable gain instrumentation amplifierpipeline a high-performance processor structure in which the co

Strona 75

Glossary© National Instruments Corporation G-15 NI 5102 User ManualRRAM random-access memoryreal time a property of an event or system in which data i

Strona 76

GlossaryNI 5102 User Manual G-16 ni.comRpprobe resistanceRSE referenced single-ended mode—all measurements are made with respectto a common reference

Strona 77

Glossary© National Instruments Corporation G-17 NI 5102 User ManualSC_TC scan counter terminal count signalSCXI Signal Conditioning eXtensions for Ins

Strona 78

© National Instruments Corporation ix NI 5102 User ManualAbout This ManualTheNI5102isananaloginputdeviceavailableinPCI,PXI,ISA,PCMCIA, and USB form fa

Strona 79

GlossaryNI 5102 User Manual G-18 ni.comswitchless device devices that do not require dip switches or jumpers to configure resourceson the devices—also

Strona 80

Glossary© National Instruments Corporation G-19 NI 5102 User ManualUunipolar a signal range that is always positive (for example, 0 to +10 V)update th

Strona 81

GlossaryNI 5102 User Manual G-20 ni.comWWwattswaveform multiple voltage readings taken at a specific sampling rateword the standard number of bits tha

Strona 82

© National Instruments Corporation I-1 NI 5102 User ManualIndexAAC/DC coupling change settling rates(table), 4-7acquiring data, 1-2 to 1-5interactive

Strona 83

IndexNI 5102 User Manual I-2 ni.comDdata acquisition. See acquiring data.digital trigger specifications, A-4 to A-5digitizersADC resolution, 3-4analog

Strona 84

Index© National Instruments Corporation I-3 NI 5102 User ManualPFIlines,4-20to4-21input lines, 4-20output lines, 4-20 to 4-21random interleaved sampli

Strona 85

IndexNI 5102 User Manual I-4 ni.comNI-DAQ driver softwareoverview of NI-DAQ API, 1-4relationship with programmingenvironment and hardware (figure), 1-

Strona 86

Index© National Instruments Corporation I-5 NI 5102 User ManualScope Soft Front Panel, 1-3serial communications port (AUX), 4-6signal connections, 4-5

Strona 87

About This ManualNI 5102 User Manual x ni.comNI 5102 NI 5102 is a generic term that denotes one or more of the NI 5102 (PCI),NI 5102 (PXI), NI 5102 (I

Komentarze do niniejszej Instrukcji

Brak uwag